PCI BDM Section 20.5.4.2.5
AASHTO LRFD
Article 5.11.3.2.3
Article 5.11.4.5.2
Article 5.11.4.5.5
Note |
---|
Ductile Regions have the Cut-Off length automatically added to them in the program output |
Transverse reinforcement is divided into 3 zones which vary from PCI BDM to AASHTO LRFD. PCI BDM defines these zones as Ordinary, Intermediate, and Special. AASHTO LRFD defines these zones as “Seismic Zone 1”, “Seismic Zone 2”, and “Seismic Zones 3 and 4”.
...
LRFD Eq. 5.6.4.6-1
LRFD Eq. 5.11.4.1.4-1
LRFD Eq. 5.11.4.1.4-2
LRFD Eq. 5.11.4.1.4-3
ACI
ACI defines their zones to be aligned with the 2018 IBC. ACI uses Seismic Design Categories (SDC) and 318-19 breaks them into 3 distinct sections. Section one is SDC A&B, section two is SDC C, and section three is SDC D,E, & F.
PCI