Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

v3.3.0.0

  • Cracking limit check clarified and has no options

    • Mu < Mcr for strength combinations

    • phiMn > 1.2Mcr

    • Both

  • Add option for solid zones

    • Can be treated as partially composite or fully composite

    • These are only sections where some insulation is present. End blocks are not considered as the insulation has been fully removed.

v3.2.4.0

  • New options for checking Mcr

  • Fix issue taking debonded strand longer than anticipated to develop

  • Updates to loss routine

  • Fix error in restrained thermal analysis

  • Misc. bug fixes

v3.2.3.0

  • Fix coordinate system on 3D Model

  • Fix for importing panels into the panel stack

  • Fixed issue causing internal soil loading to be applied on the exterior face

  • Changed reaction descriptions to make direction of load more apparent

v3.2.2.0

  • Fixed issue when using all face lifters on one crane line that would result in incorrect lifter forces

v3.2.1.0

  • Fixed display error on shear and flexure graph for strength combinations

v3.2.0.0

  • Axial utilization on performance summary is not for the pure axial case and is no longer the combined axial and flexure case

  • Now check that 2nd order effects do not increase moment by more than 40%, not longer check kl/r > 100

  • User can now define analysis points and result points from the file menu

  • Added option to use ACI 22.5.8.2 for shear capacity

  • Added analysis option to use a single crane line for all face lifters when ground reaction is present

  • Fix incorrect labels / units on the horizontal shear tables

  • Fixed printing issue

  • Fixed multiple display issues

  • No labels