Select which bars you would like epoxied, the options are ‘none’, ‘top steel if fill < 2ft’, ‘all top slab steel’, and ‘all steel’. If ‘top steel if fill < 2ft’  is selected the program will always assume the top layer of steel in the top slab is epoxy coated for fill depths less than 2 feet. Otherwise, all steel in the culvert is assumed to be uncoated at all fill depths. If ‘all steel’ is selected, the program will assume all steel is epoxy coated at all fill depths.

...

Select the appropriate exposure option for your design, the options are ‘normal’ and ‘severe’. This is used in computing the environmental durability factors, defined in ACI-350.

Additional Analysis Points:

Starting in v6.0.0, uses have the ability to add additional points that they would like data displayed for in the Text Report. To do this, select the appropriate checkboxes for the location you would like to add and enter the location. All locations are measured from the centerline of the orthogonal member.

For example, to add an additional an additional analysis point in the wall 10” below the centerline of the top slab, you would check the option for “Walls: Top” and enter “10.0” in the text box.

...

Additionally, if you’d like to add additional analysis points 24” from the centerline of both walls, you’d select the “left” and “right” options and enter “24.0” to each textbox.

...

Creating additional analysis points will display extra information in the following locations:

  • “Unfactored Moments/Shears Due to All Loads” tables:

    Image Added
  • “Unfactored Moments and Shears Due to Truck Loads” tables:

    Image Added
  • “Load Combination Results at Tenth Points” table:

    Image Added