Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Eriksson Culvert follows the seismic analysis procedure outlined in FHWA-NHI-10-034 chapter 13. Below is an example calculation of this analysis, as well as the corresponding Eriksson Culvert file.

...

Design Parameters

...

Geometric Parameter

Value

Clear span

17.667 ft

Clear Height

11.667 ft

Slab thicknesses

14 in

Wall thicknesses

14 in

Joint Location

36 in up from center line

Fill depth

16 ft

Haunch dimensions

15 in depth and width

Seismic Parameter

Value

Soil density

130 pcf

Poisson’s ratio of soil

0.5

Peak ground acceleration

0.42

Ground shear modulus

1460 ksf

Slip interface

full slip

Estimate the Free-Field Ground Strain

...

where 𝜏max is the maximum earthquake induced shear stress,

...

For this example,

...

Per WSDOT BDM section 8.3.4B, the ground acceleration (PGA) can be reduced according to the depth of fill. The ground motion attenuation is shown in table 1 (below). For a fill of 16', the ratio of ground motion to motion at burried buried structure is 1.0.

...

Calculate the Free-Field Relative Displacement

...

The flexibility ratio is defined as,

...

where w is the total culvert design width and h is the total culvert design height.

...

Calculate the Racking Ratio

...

The internal forces can be determined through analyzing a 2D frame model with a displacement of 0.273”; though due to the formulation of FEM, it is easier to apply this as an equivalent point load of 98.09 06 kips.

...

Eriksson Culvert calculates and stores these internal forces (axial, shear, and moments) at tenth points along all members in the structure for later use in the load combination equations.

...

Now the vertical force is calculated as,

...

For a rigid foundation model, an equivalent upward force is also applied to the bottom slab.

Eriksson Culvert calculates and stores these internal forces (axial, shear, and moments) at tenth points along all members in the structure for later use in the load combination equations.

...

Eriksson Culvert uses the internal forces from both analyses to develop unfactored EQ min/max envelopes for every member in the structure. The considered cases to develop these envelopes are:

  1. Results from the racking analysis

  2. Results from the vertical analysis

  3. Racking + vertical analysis results

Users have the option of determining how ‘(3) Racking + vertical analysis results’ are calculated, by either of the following combinations:

  1. 1.0 / 1.0, which includes:

    1. 1.0 H + 1.0 V

    2. -1.0 H - 1.0 V

    3. -1.0 H + 1.0 V

    4. 1.0 H - 1.0 V

  2. 0.3 / 1.0, which includes:

    1. 0.3 H + 1.0 V

    2. -0.3 H - 1.0 V

    3. -0.3 H + 1.0 V

    4. 0.3 H - 1.0 V

    5. 1.0 H + 0.3 V

    6. -1.0 H - 0.3 V

    7. -1.0 H + 0.3 V

    8. 1.0 H - 0.3 V

These unfactored forces are then applied in the LRFD extreme event I load combination:

...

Results in Eriksson Culvert

The following seismic specific results are found in the Eriksson Culvert text report:

...

View file
nameEC Seismic Example.etcx