v3.3.0.0
Cracking limit check clarified and has no options
Mu < Mcr for strength combinations
phiMn > 1.2Mcr
Both
Add option for solid zones
Can be treated as partially composite or fully composite
These are only sections where some insulation is present. End blocks are not considered as the insulation has been fully removed.
v3.2.4.0
New options for checking Mcr
Fix issue taking debonded strand longer than anticipated to develop
Updates to loss routine
Fix error in restrained thermal analysis
Misc. bug fixes
v3.2.3.0
Fix coordinate system on 3D Model
Fix for importing panels into the panel stack
Fixed issue causing internal soil loading to be applied on the exterior face
Changed reaction descriptions to make direction of load more apparent
v3.2.2.0
Fixed issue when using all face lifters on one crane line that would result in incorrect lifter forces
v3.2.1.0
Fixed display error on shear and flexure graph for strength combinations
...