The Add Detailing Steel dialog window contains four tabs along the left side for each type of reinforcement. The right side of the window has a Summary Sketch that shows where the selected steel would be placed in a wall with an opening.

Table of Contents
minLevel1
maxLevel7

Openings

On the Openings tab reinforcing steel can be defined to go around all openings in the chosen wall.

...

  • Include Perimeter Bars must be checked to include perimeter steel around the wall panel.

  • Perimeter Bar Size can vary from 3 to 6.

  • Cover Edge of Panel provides the cover distance around the panel.

  • Transverse Bar Offset sets the transvers bars to be offset up or down from the longitudinal bars or not offset at all.

  • Number of Layers can be set to 1, 2 or 3. When the number of layers are selected inputs for the depth of each layer will be made available.

  • First/Second/Third Layer Depth are inputs for the depth of each layer.

Wall Pier

On the Wall Pier tab steel reinforcement can be defined for wall piers. To place wall pier reinforcement in the wall panel opening and perimeter steel must also be placed in the wall since the stirrups for wall piers wrap around perimeter and opening steel.

...

  • Include Wall Pier Reinforcement must be checked to include wall pier reinforcement in the panel. Use Opening Detailing Steel and Include Perimeter Bars must also be checked.

  • Reinforcement Type can be set as Stirrups or Stirrups for Seismic. Stirrups for Seismic uses hooked bars for the opening steel above and below openings.

  • Max Wall Pier Width is the maximum distance between an opening and the edge of the panel for placing wall pier reinforcement.

  • Stirrup Spacing is the spacing between centerline of stirrups.

  • Stirrup Family is the stirrup Revit family to use for stirrups in the model.

  • Stirrup Type is the stirrup Revit family to use for stirrups. This drop-down box can be left blank.

Transverse

On the Transverse tab zones of transverse reinforcement can be defined and placed in the selected wall panel. Transverse steel will be automatically cut at openings.

...

  • Include Transverse Reinforcement must be checked to include transverse steel in the wall panel.

  • Add Row adds a new zone to the transverse reinforcement grid.

  • Remove Row deletes the selected zone from the grid.

  • Zone Start is the distance along the length of the wall panel at which to start the transverse zone.

  • Zone End is the distance along the length of the wall panel at which to end the transverse zone.

  • Spacing is the distance from centerline of adjacent stirrups.

  • Bar Size can be set to 3, 4, 5, 6 or 7.

  • Left Cover denotes the cover of the left side of the bar at the panel edge or an opening.

  • Right Cover is the cover of the right side of the bar at the panel edge or an opening.

  • Depth is the distance of the transverse zone into the wall panel.

Settings File

The inputs and values from all tabs in the Add Detailing Steel dialog can be saved to and loaded from a settings file. Save Settings File will open a save file dialog box to enter a file name and save all of the settings to a file. Load Settings File will show an open file dialog box to find a settings file and the load its values into the Add Detailing Steel dialog.

Run