Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Eriksson Beam, Eriksson Column, and Eriksson Wall all have support for automatic The load patterning . This algorithm takes a given load combination and creates a set of sub load combinations for it to check. For example, a load combination containing wind would not apply both pressure and suction at the same time, but instead apply all the loads with both pressure followed by all the loads with suction.

Mandatory Patterns

Wind , and Seismic, and Earth all both have mandatory load patterning that the user cannot disable.

Load Type

Description

Wind

Splits the load combination into one with pressure, and one with suction.

Seismic

Due to not knowing the direction of the acceleration from the seismic event, the seismic loads are all reversed in direction and run again

.

Earth

Typically fill soil can be removed and can potentially be a resisting force

.

Because of this a second combination is run replacing all earth loads with a minimum earth load factor instead of the load combinations factor, typically 0.

Live Load Patterning

Live loads are patterned first by grouping them based on their span and by which side of the member is load is on. Specifically, for distributed point loads we look at the direction of the applied load and for point moments we look at the sigh of the applied moment. From here, we alternate the loads based on their applied moments from one span to the next, so for a 3 span system the two cases are +, -, + and -, +, - where the sign denotes the sign of the applied moments.

...