Wind and seismic both have mandatory load patterning that the user cannot disable.

Load Type

Description

Wind

Splits the load combination into one with pressure, and one with suction.

Seismic

Due to not knowing the direction of the acceleration from the seismic event, the seismic loads are all

reversed in direction and run again

checked in all directions.

Live Load Patterning

Live loads are patterned first by grouping them based on their span and by which side of the member is load is on. Specifically, for point loads we look at the direction of the applied load and for point moments we look at the sigh of the applied moment. The following patterns are checked for both X and Y directions: All loads on one face, all loads on the opposite face, alternating face between supports. More information on load patterns checked can be found on the load summary section of the output.

...