For STND and AREMA, we only have one load combination to check:

            Loading = 1.3(DL) + 2.17(L+I)                 (STND)

            Loading = 1.4(DL) + 2.33(L+I)                 (AREMA)

 In the above equation, DL includes concrete, soil and water dead loads.

...

For maximum vertical load on the roof and maximum outward load on the walls,

DCmax + DWmax + EVmax + EHmin + (LL+IM)max + WAmax.

For minimum vertical load on the roof and maximum inward load on the walls,

DCmin + DWmin + EVmin + EHmax + LSmax

For maximum vertical load on the roof and maximum inward load on the walls,

DCmax + DWmax + EVmax + EHmax + LSmax + (LL+IM)max

 

For CHBDC, we check five load combinations:

            For maximum vertical load on the roof and minimum horizontal inward on the walls,

            DCmax + DWmax + EVmax + (LL+IM)max + EHmin + WAmax

            For maximum vertical on the roof and maximum horizontal inward on the walls,

                        DCmax + DWmax + EVmax + (LL+IM)max + EHmax + WAmin

            For minimum vertical on the roof and maximum horizontal inward on the walls,

            DCmin + DWmin + EVmin + EHmax + WAmin

            For maximum vertical on the roof and maximum horizontal inward on the walls,

            DCmax + DWmax + EVmax + LSmax + EHmax + WAmin

            For minimum vertical on the roof and maximum horizontal inward on the walls,

            DCmin + DWmin + EVmin + LSmax + EHmax + WAmin