Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

v6.0.1

10 Oct 2022

  • Bug Fixes:

    • Corrected error causing program to crash for 3 and 4 cell culverts

    • Corrected sign of reported EV shear force at the wall joints of type II culverts

    • Corrected minor interface issues for inverted 3-sided culverts

v6.0.0

26 Sep 2022

  • New Features:

    • WSDOT agency

    • Ability to calculate EH loads through the following methods:

      • Soil equivalent earth pressure (used in all designs prior to v6.0.0)

      • Active earth pressure

      • At-rest earth pressure

    • Ability to model culvert on flexible foundation

    • Allow user to select ASTM steel for automatic calculation of gamma factor 3 (on Material Properties window)

    • New options for when the effects of LL can be neglected

    • New options for how vertical and horizontal seismic forces combine

    • Allow users to define free-field ground strain for the seismic analysis

    • Allow both internal and external water to be analyzed in the same design

    • Allow the input of negative pressure heads (for when the water level is below the top slab)

    • Added new option to epoxy all steel in top slab

    • Displaying unfactored seismic analysis results in the results graphs

  • Bug Fixes:

    • Corrected reported midspan deflection, for cases when 1/9999 was displayed

...